Beckman Coulter, Inc.
 

Products

   
   
 
 

  DTX Series Multimode Detectors-- Specifications and Ordering Information

Printer Friendly


Related Product Information

Specifications

 
DTX 800
DTX 880
General
Light Source
High Power LEDs
High Power LEDs + Deuterium Lamp
Detectors Silicon Photodiode + PMT
Filters
1 EX + 1 EM Filter Slides (6 filter capacity)
 
2 EX + 1 EM Filter Slides (6 filter capacity)
Plate Formats
96-384 well
 
6-384 well
Measurement Methods Endpoint, Kinetic, Linear Scan, Area Scan
Shaking

Linear + Orbital (3 speeds)

Temperature Control

…..
 

Ambient +4°C to 45°C
Power/Voltage 100-240VAC; 50/60Hz
Dimensions 39cm W x 24cm H x 58cm L
Weight 25 kg
Fluorescence Intensity-Top Read
Wavelength Range
 
340-650nm
 
230-750nm
Detection Limit--96 well plate
 
10 fmol/200µl fluorescein
 
1.5 fmol/200µl fluorescein
Detection Limit--384 well plate
 
5 fmol/100µl fluorescein
 
1.5 fmol/100µl fluorescein
Linear Dynamic Range
 
5 decades
Read Time (Fly mode)
 
18sec/96well; 37sec/384well
Fluorescence Intensity-Bottom Read
Wavelength Range
 
…..
 
300-650nm
Detection Limit--96 well plate
 
…..
 
50 fmol/200µl fluorescein
Detection Limit--384 well plate
 
…..
 
25 fmol/100µl fluorescein
Time-Resolved Fluorescence
Wavelength Range
 
…..
 
340-750nm
Detection Limit--96 well plate
 
…..
 
50 amol/200µl Europium
Detection Limit--384 well plate
 
…..
 
30 amol/100µl Europium
Linear Dynamic Range
 
…..
 
5 decades
Read Time (1sec integration)
 
…..
 
180sec/96well; 690sec/384well
Fluorescence Polarization
Wavelength Range
 
…..
 
300-750nm
Detection Limit--96 well plate
 
…..
 
5 mP at 10nM Fluorescein
Detection Limit--384 well plate
 
…..
 
5 mP at 10nM Fluorescein
Read Time (Fly mode)
 
…..
 
38sec/96well; 79sec/384well
Luminescence (Glow)
Wavelength Range
 
400-650nm
 
400-750nm
Detection Limit--96 well plate
 
2 fmol ATP
Linear Dynamic Range
 
5 decades
Read Time (Fly mode)
 
18sec/96well; 37sec/384well
Absorbance
Wavelength Range
 
340-650nm
 
230-650nm
Indication Range
 
0-3.5 OD
Accuracy
 
<+1%+10mOD at 2 OD
Reproducibility
 
<+0.5% and +0.005 OD at 2 OD
Read Time
 
18sec/96well; 37sec/384well
Operating System
CPU
 
Pentium II 300Mhz
RAM
 
128MB min, 256MB recommended
Hard Drive
 
150MB free space
Serial Port
 
1 free port
Operating Systems
 
Windows NT4, 2000, XP

* Actual read time depends upon plate format and protocol configurations. Fly mode read times represent the fastest


 

Ordering Information 

Part No. Description
987920 DTX 800 Multimode Detector Includes DTX 800 Multimode Detector, Excitation Filter Slide #3 (Absorbance: 405nm, 450nm, 492nm, 620nm; Fluorescence: 360nm, 485nm), Emission Filter Slide #3 (Fluorescence: 465nm, 535nm), Multimode Detection Software, Power Cable, RS-232 Serial Cable, Instrument and Software User’s Manuals
987921 DTX 880 Multimode Detector Includes DTX 880 Multimode Detector, Excitation Filter Slide #1 (Fluorescence: 485nm, 535nm; TRF: 370nm; FP: 485nm), Emission Filter Slide #1 (Fluorescence: 535nm, 595nm, 625nm; FP: 535nm x 2), Excitation Filter Slide #2 (Absorbance: 260nm, 340nm, 405nm, 450nm, 595nm, 620nm), Multimode Detection Software, Power Cable, RS-232 Serial Cable, Instrument and Software User’s Manuals
 

Note: Minimum operating system requirements for Multimode Detection Software are: Windows version NT4/2000/XP (English version); Pentium II 300Mhz CPU; min. 128MB RAM; 150MB available on hard drive; and 1 free serial port.

back to top



 

 
 
Home | Products | Customer Support | Resource Center
Employment | Our Company | Contact Us | Site Map
 Privacy©1998 - 2008 Beckman Coulter, Inc.