Standard Single-Position ALP
|
|
Includes single-position ALP for positioning of one (1) standard 96- and/or 384-well
microtiter plates as singles or in stacks with spacing to support Biomek gripper and/or
robotic manipulation. The single position ALP can be placed in any open position.
|
| Part No. |
Description |
| 719357
|
Standard Single-Position ALP
|
|
|
|
|
Standard Three-Position ALP
|
|
A three-position ALP for positioning of three (3) standard 96 and/or 384 well microtiter plates as singles or in stacks with spacing to support Biomek NX gripper and/or robotic manipulation. The three-position ALP can be placed in any column in the work area with the front three rows open.
|
| Part No. |
Description |
| 719358
|
Standard Three-Position ALP
|
|
|
|
|
Standard Five-Position ALP
|
|
A five-position ALP for positioning of five (5) standard 96 and/or 384 well microtiter plates or reservoirs. The five-position ALP DOES NOT support Biomek NX gripper and/or robotic manipulation, and is ideally used to locate reagents, etc. that do not require re- location. The five-position ALP can be placed in any column in the work area with all rows open.
|
| Part No. |
Description |
| 719359
|
Standard Five-Position ALP
|
|
|
|
|
High-Density Twelve-Position 4x3 ALP
|
|
For use on an FXP/FX System or NXP/NX Multichannel System. Includes twelve-position ALP for
positioning of twelve (12) standard 96- and/or 384-well microtiter plates as singles or in stacks
with spacing to support Biomek gripper manipulation. This twelve-position ALP covers the
entire work area excluding the outer columns.
CANNOT be used with Biomek NXP/NX Span-8 Systems
|
| Part No. |
Description |
| 719948
|
High-Density Twelve-Position 4x3 ALP
|
|
|
|
|
Biomek NXP/NX Span-8 4x3 ALP Kit
|
|
Biomek NXP/NX Span-8 4x3 ALP Kit is designed specifically for use on the Biomek NX Span-8.
The 4x3 ALP's positions are slightly more compact than that of the regular Biomek FXP/FX/NXP/NX
Multichannel 4x3 ALP. This ALP is used with the Biomek NXP/NX Span-8 if additional
deck space is required.
CANNOT be used with Biomek FXP/FX or Biomek NXP/NX Multichannel Systems
|
| Part No. |
Description |
| 989839
|
Biomek NXP/NX Span-8 4x3 ALP Kit
|
|
|
|
|
Waste (Multichannel) ALP
|
|
The waste ALP chute is for the disposal of full or empty tip racks and microtiter plates from the work area of the Biomek NXP/NX . The removal of the chute and the addition of the disposal bags will provide of the disposal of 7 heads of tips without their racks into the waste disposal bag. ALP requires a single position in the outer columns in rows 2 or 3 of the Biomek NXP/NX work area.
|
| Part No. |
Description |
| 719347
|
Waste (Multichannel) ALP
|
|
|
|
|
Waste (Span-8) ALP
|
|
The waste ALP chute is for the disposal of the Span-8 pipettor. The chute can be removed and replaced with a disposal bag. The waste ALP requires a single position in the outer columns in rows 2 or 3 of the Biomek NXP/NX work area.
|
| Part No. |
Description |
| 719590
|
Waste (Span-8) ALP
|
|
|
|
|
Biomek NXP/NX Half Trash ALP Kit
|
|
Designed to occupy only half of a regular single deck position. Ideally for use with the Span-8
Wash Station. Combined , the Span-8 Wash Station (P/N 719654) and the Half Trash ALP only
occupy a single deck position saving valuable space for other ALP functions.
|
| Part No. |
Description |
| 989778
|
Biomek NXP/NX Half Trash ALP Kit
|
|
|
|
|
Biomek Source/Waste Sensor Kit
|
|
Kit includes a sensor box assembly which connects sensors to liquid source and waste. Sensors
are attached to lengths of Velcro straps which are used to attach the sensors to source and waste
containers. Source sensor is attached to a 24"strap and waste sensor is attached to a 42" strap.
The unit waste source sensor unit is connected to the Biomek instrument via the CAN bus.
When a sensor is activated, an error dialog box will appear alerting the user that the waste or
source containers need attention.
|
| Part No. |
Description |
| 987789
|
Biomek Source/Waste Sensor Kit
|
|
|
|
|
Biomek NXP/NX Solid Phase Extraction ALP Platform
|
|
This ALP is designed for use with the vacuum filtration systems and is the support ALP for the vacuum manifold. Placement of this ALP should allow space for gripper access and tubing This ALP should be ordered in conjunction with the SPE ALP Collar platform (P/N 719229).
|
| Part No. |
Description |
| 717632
|
Biomek NXP/NX Solid Phase Extraction ALP Platform
|
|
|
|
|
Biomek NXP/NX Solid Phase Extraction ALP Collar Platform
|
|
This ALP is designed for use with the vacuum filtration systems and is the location for Filtration collars during assembly, disassembly, and reassembly. This ALP is typically positioned adjacent to the SPE ALP Platform to afford maximum efficiency of motion. This ALP should be ordered in conjunction with the SPE ALP platform (P/N 717632)
|
| Part No. |
Description |
| 719229
|
Biomek NXP/NX Solid Phase Extraction ALP Collar Platform
|
|
|
|
|
Biomek Single Position ALP with Indented Sides
|
|
This ALP is designed for positioning one (1) standard 96 or 382 well microtiter plate. The indented sides of the ALP accommodate the Biomek Gripper tool and robotic manipulations used with specific protocols on the Biomek.
|
| Part No. |
Description |
| 719804
|
Biomek Single Position ALP with Indented Sides
|
|
|
|
|
Adaptor for Biomek Tube Racks, 3-Position
|
|
A three-position ALP for positioning of three (3) standard Biomek Test Tube Racks: Test Tube Rack - 160, 10 mm Tubes (P/N 609046), Test Tube Rack - 128, 12 mm Tubes (P/N 609050), or Test Tube Rack - 96, 13 mm Tubes (P/N 609051). The three-position ALP can be placed in any column in the work area.
|
| Part No. |
Description |
| 719672
|
Adaptor for Biomek Tube Racks, 3-Position
|
|
|
|
|
Adaptor for Biomek Tube Racks, 2-Position
|
|
A two-position ALP for positioning of two (2) standard Biomek Test Tube Racks: Test Tube Rack - 160, 10 mm Tubes (P/N 609046), Test Tube Rack - 128, 12 mm Tubes (P/N 609050), or Test Tube Rack - 96, 13 mm Tubes (P/N 609051). The two-position ALP can be placed in any column in the work area. It can also be placed on an outer column along with the Span-8 Waste ALP.
|
| Part No. |
Description |
| 719337
|
Adaptor for Biomek Tube Racks, 2-Position
|
|
|
|
|
Test Tubes ALPs and Racks
|
|
|
|
24-Position Tube Rack fits onto Biomek NXP/NX Standard ALP to holds various-sized polystyrene, polypropylene, and polyallomer tubes, Microfuge® Tubes and cryovials. To ensure proper tube fit, inserts must be used. Due to variations among manufacturers, tubes and cryovials should be measured prior to selecting an insert. Measure one inch from the tube bottom and select the insert with the appropriate diameter, or check for size using inserts from your starter kit
Test Tube Racks fit onto Biomek NXP/NX 2-position or 3-position ALPs, P/N 719337 or 719672 respectively.
|
| Part No. |
Description |
| 373661
|
24-Position Tube Rack (Qty. 1)
|
|
|
|