As part of the Biomek 3000, highly specialized precision tools and disposable pipette tips are available to perform sample preparation and assay requirements with complete accuracy. A plate reader, unique modular reservoir system, and proprietary labware offer added flexibility for life science applications.
Tips and Labware
|
|
Thermal Exchange Unit
|
|
|
|
The Thermal Exchange Unit (TEU) accessory heats or cools a reservoir, plate or other standard labware on the Biomek 3000 worksurface. The unit snaps into any Biomek 3000 worksurface location and a regular Biomek labware holder (not included) fits into the top, ready to accept labware. Temperature is controlled via a user-supplied circulator bath.
|
| Part No. |
Description |
| 148275
|
Biomek Thermal Exchange Unit and Reservoir Holder Kit Includes Thermal Exchange Unit, Thermal Reservoir Holder, Tubing and Manual
|
|
|
|
|
Biomek Circulating Reservoir and Replacement Parts
|
|
|
|
The Circulating Reservoir for the Biomek 3000 provides a continuous supply of buffers, solvents or reagents on the Biomek worksurface. A four-well Teflon* reservoir is placed in one position on the Biomek worksurface. A peristaltic pump circulates liquid between two wells of the reservoir and glass supply bottles. A second pump may be added to circulate a total of four liquids. Liquid temperature can be regulated by placing the supply bottles in a user-supplied circulator bath.
|
| Part No. |
Description |
| 148086
|
Biomek Circulating Reservoir Kit Includes four-well Teflon reservoir and accessories for circulation of two liquids. Includes pump, four pump heads, two 1.1 L supply bottles with delivery caps, Tygon and PharMed tubing, and manual.
|
| 148087
|
Biomek Circulating Reservoir Two-Well Pump Kit Includes pump, four pump heads, two 1.1 L supply bottles with delivery caps, Tygon and PharMed tubing.
|
| 148028
|
1.1 L Reservoir Bottle
|
| 148029
|
5.0 L Reservoir Bottle
|
| 148030
|
Reservoir Delivery Cap
|
| 148031
|
Tubing/Fitting Replacement Kit, Tygon
|
| 148032
|
Tubing/Fitting Replacement Kit, PharMed
|
|
|
|
|
Modular Reservoir Systems and Reservoir Frames
|
|
|
|
The Modular Reservoir System holds liquids for pipetting with the Biomek 3000 and Beckman Coulter manual pipettors. Full reservoirs hold up to 150 mL of liquid, and do not require a frame. Half and quarter reservoirs are available, which must be used with a frame. Each frame can accommodate up to four quarter reservoirs or two half reservoirs, or variations thereof. All reservoirs are sterile and made of polypropylene. Nonpyrogenic reservoirs are available.
|
| Part No. |
Description |
| 372790
|
Quarter Reservoir
|
| 534680
|
Quarter Reservoir, Nonpyrogenic
|
| 372792
|
Quarter Reservoir, Divided by Width
|
| 372788
|
Quarter Reservoir, Divided by Height
|
| 372786
|
Half Reservoir
|
| 534681
|
Half Reservoir, Nonpyrogenic
|
| 372794
|
Half Reservoir, Divided by Width
|
| 372784
|
Full Reservoir
|
| 534678
|
Full Reservoir, Nonpyrogenic
|
| 372795
|
Frame for Reservoirs
|
|
|
|
|
DPC Micromix 5 Orbital Shaker
|
|
|
|
For use with the Biomek 2000/3000 for application requiring orbital shaking, the Micromix 5 integrates on either the right or left side for convienent access by the gripper & pipetting tools. Two positions are accessible by the workstation with specially designed labware holders to secure plates during vigorous shaking. Ships direct from Beckman Coulter
|
| Part No. |
Description |
| 380560
|
DPC Orbital Shaker
|
| 380561
|
DPC Shaker Integration Kit for Biomek 2000/3000 Includes mounting brackets, support legs for Biomek 2000/3000, shaker top plate, two shaker labware holders, communications cable, instructions and installation.
|
|
|
|
|
Gripper Tool
|
|
|
|
The Gripper Tool provides the researcher with the capability to automatically move plates, reservoirs, and filtration manifold collars on the Biomek 3000 worksurface. The tool is especially useful for loading plate readers and filtration manifolds for applications such as ELISA's, DNA purification, and receptor binding assays.
Note: The Gripper Tool requires the Biomek Software 3.0 or later to operate.
|
| Part No. |
Description |
| 986129
|
Gripper Tool System for Biomek 3000 Includes Gripper Tool, Gripper Tool Rack, Calibration Plate, Disposal Option, Disposal Bags, Manual and spare Finger Pads.
|
| A09053
|
Gripper Tool Kit for Biomek 3000 Includes Gripper Tool, Gripper Tool Rack, and spare Gripper Pads. For customers who have separately purchased the Disposal Option (P/N 609751) or who do not intend to use that option.
|
| 609736
|
Labware/Collar Holder
|
| 987371
|
Biomek 3000 Gripper Tool
|
| 609641
|
Gripper Tool Rack
|
| 609726
|
Gripper Calibration Plate
|
| 609088
|
Finger Pad Replacement Kit for Gripper Tool and Side Loader Hand Includes 12 pads, adhesive and instructions.
|
|
|
|
|
96-Filtration System
|
|
|
|
96-Filtration System: Vacuum-Based Separations in Microplate Format. Configurations for benchtop use or with the Biomek 3000 Laboratory Automation Workstation. Square-well and standard microplate collection capability.
|
| Part No. |
Description |
| A15925
|
96-Filtration System Includes filtration manifold and stand, microplate collar and square-well collar, vacuum regulator, tubing kit and user's manual. Recommended for manual operation.
|
|
|
|
|
Test Tube Racks
|
|
|
|
High-capacity Test Tube Racks hold glass, polystyrene, polypropylene, and polyallomer tubes up to 100 mm in length. Requires Test Tube Rack Holder (P/N 609052).
|
| Part No. |
Description |
| 609046
|
10 mm Test Tube Rack, holds up to 160 tubes
|
| 609050
|
12 mm Test Tube Rack, holds up to 128 tubes
|
| 609051
|
13 mm Test Tube Rack, holds up to 96 tubes
|
|
|
|
|
Spill Trays
|
|
For added protection against spills, spill trays can be placed under the Biomek 3000 worksurface and side module covers.
|
| Part No. |
Description |
| 987199
|
Worksurface Spill Tray
|
| 609078
|
Side Module Spill Tray, for left or right side module
|
|
|
|
|
Side Modules
|
|
|
|
The Biomek 3000 worksurface can expand from 8 10 12 selectable positions with the use of side modules. Installed in the right or left expansion areas of the Biomek 3000, each side module adds two selectable positions to the worksurface. Both side modules are required for the maximum worksurface capacity of 12 positions. Each side module holds two labware or pipette tip rack holders, two tool racks or one test tube holder. The side module cover is removable for easy cleaning, and a side module spill tray (P/N 609078) can be installed for added protection against liquid spills.
|
| Part No. |
Description |
| 987263
|
Right Side Module
|
| 987264
|
Left Side Module
|
|
|
|
|
Automatic-Latch Tip Rack System
|
|
|
|
A Latch Controller and Automatic-Latch Tip Rack Holder are utilized to facilitate automated movement of tip racks onto and off of the Biomek 3000 work surface.
• Holders are automatically opened and closed by the software when a Gripper tool or side Loader hand places a tip rack in or removes a tip rack from an automatic-latch holder.
• Required if tips are going to be supplied to the Biomek 3000 work surface from a Stacker Carousel
|
| Part No. |
Description |
| A15927
|
Latch Controller with Automatic-Latch Tip Rack Holder Includes Latch Controller and two Automatic-Latch (A-L) Tip Rack Holders. Up to 10 additional A-L Tip Rack Holders may be controlled by the Controller. For use with Biomek Stacker Carousel and Side Loader. Requires BioWorks 3.1 or later.
|
| 989969
|
Automatic-Latch Tip Rack Holder Requires Latch Controller.
|
| 148249
|
Automatic Latch Controller Unit Requires Biomek System Software.
|
|
|
|
|
Tool Rack and Labware Holders
|
|
|
|
Biomek Tool Rack and Labware Holders allow placement of interchangeable tools, pipette tip racks, multiwell plates, reservoir holders, 24-place tube racks and test tube racks on the Biomek 3000 worksurface. The tool rack, labware and pipette tip rack holders use single worksurface positions, and the test tube rack holders require two worksurface positions.
|
| Part No. |
Description |
| 609119
|
Tool Rack Holds five liquid handling tools or one HDR tool.
|
| 609120
|
Labware Holder Gray Color; holds one multiwell plate, reservoir holder or 24-place tube rack
|
| 391910
|
Pipette Tip Rack Holder Black Color; holds one P20 or P250 pipette tip rack
|
| 609052
|
Test Tube Rack Holder Holds one 10, 12, 13, or 15.5 mm test tube rack
|
| A15768
|
P1000 Pipette Tip Rack Holder Black Color; specifically for use with P1000 pipette tip
|
|
|
|
|
Disposal Option
|
|
|
|
Disposal area for tips, plates and tip rack lids on left side of Biomek worksurface. 100 Disposal Bags. For Biomek Software 3.0 and later.
|
| Part No. |
Description |
| 970577
|
Biohazard Disposal Bags, Large
|
| 609751
|
Disposal Option, Large
|
|
|
|
|
Wash Tools
|
|
|
|
Wash tools are available in single- and eight-channel versions that deliver liquid from 50 µL to 150 mL. Ideal for plate washing, cell feeding or large-volume liquid delivery, wash tools have an extended reach (40 mm) for large-volume multiwell plates, such as the Beckman Coulter Deep-Well and Square-Well titer plates. Biomek Wash Units provide accurate liquid delivery and aspiration for all washing and large-volume liquid delivery requirements and are automatically controlled by the BioWorks Operating System.
|
| Part No. |
Description |
| 987369
|
Biomek 3000 Single Channel Wash Tool
|
| 987370
|
Biomek 3000 Eight Channel Wash Tool
|
|
|
|
|
Wash Units
|
|
|
|
The wash units include a precise peristaltic pump, silicon tubing, vacuum control pinch valve, with or without a six-port valve and RS-485 communication port. A customer-supplied vacuum source with flow of 0.5 L/minute at 8 psi or better is required.
|
| Part No. |
Description |
| 609036
|
Wash Unit
|
| 609056
|
Wash Unit with Automatic Six-Port Valve
|
| 609284
|
Automatic Six-Port Valve
|
|
|
|
|
Single-Tip Pipeline Tools
|
|
|
|
The P20, P200L and P1000L pipette tools accurately transfer volumes of 1-20, 5-200 and 50- 1000 µL, respectively. The P200L and P100L include patented liquid-level sensing technology that sonically detects the meniscus for control of reagent usage and liquid transfer uniformity. All Biomek pipetting tools have liquid-level tracking capability that automatically calculates the sample height for subsequent liquid transfers. In addition, all Biomek pipette tools allow repeat pipetting of identical volumes for multiple liquid deliveries from a single sample aspiration. Single-tip tools can sample from the bottom of tubes up to 100 mm in length, provide extremely accurate pipette transfers from 1.0 µL to 1.0 mL and are compatible with a variety of Beckman Coulter Pipette Tips.
|
| Part No. |
Description |
| 987367
|
P20 Single-Tip Tool - Nominal Cap(µL): 1-20, Tip Compatibility: P20, P20 barrier P250, P250 barrier
|
| 987368
|
P200L Single-Tip Tool - Nominal Cap (µL): 5-200, Tip Compatibility: P250,P250 barrier
|
| 987366
|
P1000L Single-Tip Tool - Nominal Cap (µL): 50-1000, Tip Compatibility: P1000
|
| A17433
|
P1000L Tool Kit - Includes P1000L pipette tool (987366) and tip rack (A15768)
|
|
|
|
|
Multi-Tip Pipette Tools
|
|
|
|
The MP20 and MP200 eight-tip pipette tools accurately transfer volumes of 1-20 µL per tip and 5-200 µL per tip, respectively, for high efficiency. Multi-tip tools incorporate liquid-level tracking and repeat-pipetting capabilities. When used with any of the P250 pipette tips, the multi-tip tools reach to the bottom of Beckman Coulter Square-Well and Deep-Well titer plates or other multiwell labware up to 50 mm in length.
|
| Part No. |
Description |
| 391900
|
MP20 Eight-Tip Tool - Nominal Cap. (µL): 1-20, Tip Compatibility: P20, P20 barrier - P250, P250 barrier
|
| 986146
|
MP200 Eight-Tip Tool - Nominal Cap. (µL): 5-200, Tip Compatibility: P250,P250 barrier
|
|
|
|
|
High-Density Replicating System
|
|
|
|
Replication of microplate libraries to filters, membranes and/or daughter plates is a common and tedious task performed during life science research and drug discovery. The Biomek 2000 Laboratory Automation Workstation with the High-Density Replication (HDR) System provides automated replication with speed, precision and efficiency unmatched by human hands.
|
| Part No. |
Description |
| A15921
|
96 HDR System, 120V, 50/60 Hz Includes HDR Tool Body, 96-Pin Plate Kit and Fan Kit for 120 V, 50/60 Hz. System can be expanded with 384-Pin Plate Kit (Part No. 609079).
|
| A15922
|
96 HDR System, 240V, 50/60 Hz - Same as Part No. A15921 except 240V power).
|
| A15923
|
384 HDR System, 120V, 50/60 Hz Includes HDR Tool Body, 384-Pin Plate Kit and Fan Kit for 120V, 50/60 Hz. System can be expanded with 96-Pin Plate Kit (Part No. 609004).
|
| A15924
|
384 HDR System, 240V, 50/60 Hz - Same as Part No. A15923 except 240V power.
|
| 987373
|
Biomek 3000 96/384 HDR Tool Body
|
| 609004
|
96-Pin Plate Kit Includes one 96-pin plate with 0.015-in. pins and pin retainer installed, and one 96-pin plate with 0.045-in. pins and pin retainer installed, plus four extra pins of each size.
|
| 609079
|
384-Pin Plate Kit Includes one 384-pin plate with 0.015-in. pins and pin retainer installed, and one 384-pin plate with 0.045-in. pins and pin retainer installed, plus 16 extra pins of each size.
|
| 609002
|
96/384 Fan Kit, 120V, 50/60 Hz Includes HDR Tool Holder, fan, three reservoirs (bleach, ethanol, water) and power supply.
|
| 609003
|
96/384 Fan Kit, 240V, 50/60 Hz Same as Part No. 609002 except 240V power.
|
| 609089
|
Spare Pins, 0.015-in. diameter (20 Qty).
|
| 609255
|
Spare Pins, 0.045-in. diameter (20 Qty).
|
|
|
|
|
Stacker Carousel
|
|
|
|
The Biomek Stacker Carousel provides external supply and storage of microplates, deep-well plates, and P20 and P250 pipette tips for the Biomek 3000 Laboratory Automation Worstation. This increases capacity and walk-away operation of the Biomek 3000 for all applications.
Read More...
|
| Part No. |
Description |
| A15928
|
Stacker Carousel System for Biomek 3000, Left Side Includes Carousel for mounting of left side of Biomek 3000 workstation, Latch Controller and two Automatic-Latch Tip Rack Holders. Stacks ordered separately. Requires Biomek Gripper Tool for trasferring plates between stacker Carousel and Biomek work surface and also requires Biomek Software 3.0 or later.
|
| A15929
|
Stacker Carousel System for Biomek 3000, Right Side Includes Carousel for mounting on right side of Biomek 3000 workstation, Latch Controller and two Automatic-Latch Tip Rack Holders. Stacks ordered separately. Requires Biomek Gripper Tool for trasferring plates between stacker Carousel and Biomek work surface and also requires Biomek Software 3.0 or later.
|
| 148522
|
Stacker 10 - 10-position stack for Stacker Carousel. Accommodates lidded and unlidded Biomek P20 and P250 pipette tip racks, deep-well plates, square-well plates, reservoirs and microplates.
|
| 148246
|
Stacker 20 - 20-position stack for Stacker Carousel. Accommodates lidded and unlidded microplates.
|
| 148257
|
Stacker HD
|
|
|
|
|